Track Mounted Bulkheads

Manufactured to bespoke dimensions & specification

Track Mounted Bulkheads

Manufactured to bespoke dimensions & specification

The Cool-Guard temperature zoning, insulated bulkhead is a regular fixture in the leading temperature vehicle fleets across the UK.

Many different styles and designs are available and manufactured to your specific requirements.
The Cool-Guard core is constructed using EPS (expanded polystyrene), a closed-cell moisture resistant material designed to resist water ingress and bacteria forming.


Key Benefits

  • 75mm Overall thickness, EPS lightweight core
  • Reinforced vinyl skin
  • Extremely lightweight and robust design
  • Flush mounted bolts used in all applications
  • Heat sealed vinyl perimeter
  • Low density perimeter foam for superior compression
  • Can be supplied in a multitude of configurations
  • K-Value tested to comply with ATP Classification – documentation available upon request 

NEW Easy-Glide Aluminium Track & Roller System

Designed to offer the end-user optimum weight saving. Using aluminium components ensures the aesthectics are enhanced whilst offering strength and significant weight savings, compared to galvanized versions.

12 Metre travel split lane system - incorporates the centre 'J' track system, saving 79kgs compared to the 'industry standard' galvanized versions.

  • Increased payload
  • Increased MPG
  • Increased BHP
  • Reduction in C02 emissions
  • Rust-free guarantee

NEW CG Rotation Bar

Optional for track mounted bulkheads, the aluminium profile replaces the galvanized steel tube and hanging brackets, offering a one-piece solution with hidden fixings ensures the look and feel of a premium product, at an affordable price. 

NEW Lightweight Aluminium Rollers

Traiditional steel rollers have been upgraded to aluminium, offering a rust-free product with significant weight saving advantages. They also benefit from nylon bushes, ensuring the bar rotate smoothly.

Easy-Lift Lifting & Storing Device

The ‘Easy-Lift’ mechanism is fitted as standard on all Roof Mounted Systems, which allows the bulkhead to be effortlessly lifted and stored. The integrated ‘CG-Cleat’ grips the rope when being lifted, to avoid the bulkhead slipping and then self-locks when in the desired position, holding the unit firmly against the roof. All ‘CG-Cleats’ have been fully tested to a breaking strength of 230kgs, so you can be confident in the fact that once the bulkhead is stored, it will remain stored!

UHMWPE Skidguards

All Cool-Guard Bulkheads are fitted, as standard, with a heavy-duty PE skid-guard. This prevents damage to the bottom of the unit when being operated and scuffed along the vehicle floor. It also prevents lower damage from trolleys, cages, pallets etc., this offers a great barrier against costly repairs and down-time. The skidguard can be supplied in heights of 150mm and 250mm.

Options

  • Corner cut-outs, can be shaped to accommodate ducting/conduit etc.
  • Side wings with velcro tabs sewn onto the polyester hinge, allowing the wings to be held against the bulkhead when being stowed
  • Ventilation flaps, three different styles are available
  • Thermostatic fan kits - used where dual temperature control is required - Analogue & Digital options available

Many more options are available, please contact us for more information

One-piece

Additional options

  • Corner cut-outs, can be shaped to accommodate ducting/conduit etc.
  • Ventilation flaps
  • VF-Tech / TF-Tech Thermostatic fan kits can be supplied where dual temperature control is required, 2 options are available:
  • Analogue - recommended for retrofit applications where wiring for the probe sensor & controller may not be possible
  • Digital - recommended for new build applications where wiring for the probe sensor & controller can be incorporated into the build. The digital controller allows the operator full control of the rear compartment from the cab, whilst giving a more accurate reading

Many more options and configurations are available, please contact us for more information

 

Add To Quote

One-piece with side wings

Additional options

  • Corner cut-outs, can be shaped to accommodate ducting/conduit etc.
  • Ventilation flaps
  • VF-Tech / TF-Tech Thermostatic fan kits can be supplied where dual temperature control is required, 2 options are available:
  • Analogue - recommended for retrofit applications where wiring for the probe sensor & controller may not be possible
  • Digital - recommended for new build applications where wiring for the probe sensor & controller can be incorporated into the build. The digital controller allows the operator full control of the rear compartment from the cab, whilst giving a more accurate reading

Many more options and configurations are available, please contact us for more information

 

Add To Quote

Two-piece - bulkheads travel independently

Easy-Glide Aluminium Track & Roller System
Designed to offer the end-user optimum weight saving. Using aluminium components ensures the aesthectics are enhanced whilst offering strength and significant weight savings, compared to galvanized versions.

The 12 metre travel, split lane system incorporating the centre 'J' track system, saves 79kgs compared to the 'industry standard' galvanized versions.

  • Increased payload
  • Increased MPG
  • Increased BHP
  • Reduction in C02 emissions
  • Rust-free guarantee

 

Additional options

  • Corner cut-outs, can be shaped to accommodate ducting/conduit etc.
  • Ventilation flaps
  • VF-Tech / TF-Tech Thermostatic fan kits can be supplied where dual temperature control is required, 2 options are available:
  • Analogue - recommended for retrofit applications where wiring for the probe sensor & controller may not be possible
  • Digital - recommended for new build applications where wiring for the probe sensor & controller can be incorporated into the build. The digital controller allows the operator full control of the rear compartment from the cab, whilst giving a more accurate reading

Many more options and configurations are available, please contact us for more information

Add To Quote

Two-piece - bulkheads travel together

Additional options

  • Corner cut-outs, can be shaped to accommodate ducting/conduit etc.
  • Ventilation flaps
  • VF-Tech / TF-Tech Thermostatic fan kits can be supplied where dual temperature control is required, 2 options are available:
  • Analogue - recommended for retrofit applications where wiring for the probe sensor & controller may not be possible
  • Digital - recommended for new build applications where wiring for the probe sensor & controller can be incorporated into the build. The digital controller allows the operator full control of the rear compartment from the cab, whilst giving a more accurate reading

Many more options and configurations are available, please contact us for more information

Add To Quote

One third / two third

Additional options

  • Corner cut-outs, can be shaped to accommodate ducting/conduit etc.
  • Ventilation flaps
  • VF-Tech / TF-Tech Thermostatic fan kits can be supplied where dual temperature control is required, 2 options are available:
  • Analogue - recommended for retrofit applications where wiring for the probe sensor & controller may not be possible
  • Digital - recommended for new build applications where wiring for the probe sensor & controller can be incorporated into the build. The digital controller allows the operator full control of the rear compartment from the cab, whilst giving a more accurate reading

Many more options and configurations are available, please contact us for more information

 

Add To Quote

One-piece with centre door

Additional options

  • Corner cut-outs, can be shaped to accommodate ducting/conduit etc.
  • Ventilation flaps
  • VF-Tech / TF-Tech Thermostatic fan kits can be supplied where dual temperature control is required, 2 options are available:
  • Analogue - recommended for retrofit applications where wiring for the probe sensor & controller may not be possible
  • Digital - recommended for new build applications where wiring for the probe sensor & controller can be incorporated into the build. The digital controller allows the operator full control of the rear compartment from the cab, whilst giving a more accurate reading

Many more options and configurations are available, please contact us for more information

 

Add To Quote

Three-piece

Additional options

  • Corner cut-outs, can be shaped to accommodate ducting/conduit etc.
  • Ventilation flaps
  • VF-Tech / TF-Tech Thermostatic fan kits can be supplied where dual temperature control is required, 2 options are available:
  • Analogue - recommended for retrofit applications where wiring for the probe sensor & controller may not be possible
  • Digital - recommended for new build applications where wiring for the probe sensor & controller can be incorporated into the build. The digital controller allows the operator full control of the rear compartment from the cab, whilst giving a more accurate reading

Many more options and configurations are available, please contact us for more information

Add To Quote
All Insulated Bulkheads

Added To Your Quote

  • Track Mounted Bulkheads

    Manufactured to bespoke dimensions & specification

    Quantity: